Cassettes, towers, ductables, Mini VRF and industrial chillers
Dunham-Bush builds Comfortline cassettes, towers and ductables, DB Smart Mini VRF, the VRF-6Pro ACE and MAXes platform, floor-standing units, rooftop packages, and an AHRI-certified chiller range that runs from a 10 TR scroll machine to a 3000 TR centrifugal. Sri Engineering Works supplies, installs and services that whole range across Andhra Pradesh and Telangana — a single cabin, a hotel floor, or a central plant room.
The complete lineup of Dunham-Bush equipment, supplied with official manufacturer warranty and expert installation.
Cassette AC1.5 TR to 4 TR
Comfortline 4-way cassette
Fixed-speed and inverter 4-way cassettes on R-32. Each model below has its own specification page, from the 1.5 TR inverter to the 4 TR three-phase fixed-speed unit.
Single-phase Mini VRF outdoors from 3.5 kW to 17.5 kW cooling. They accept hi-wall, mid-static duct, 1-way cassette and 4-way cassette indoors. A multi-indoor system uses these same indoor and outdoor models.
Large floor-standing units. Heat-pump and cooling-only pairs at 6.3 TR and 8.0 TR. Each pair is one page, with the outdoor model in the specifications.
Room splits in inverter and non-inverter, cooling only and heat pump, at 1 TR, 1.5 TR and 2 TR. Ask us for the current model and a site quotation.
Inverter and non-inverter
Cooling only and heat pump
1, 1.5 and 2 TR
Ideal applicationHomes, cabins, small shops
VRF / VRV System7.2 HP to 16 HP
ACE side-discharge VRF
Side-discharge VRF from 7.2 HP to 16 HP. Indoor options include hi-wall, 4-way cassette, 2-way cassette, 1-way cassette, ducted, floor ceiling, fresh air and treated fresh air. Ask us for the current outdoor model.
7.2 HP to 16 HP
2-way cassette
Treated fresh air
Ideal applicationSide-discharge VRF, 7.2 HP to 16 HP
VRF / VRV System8 HP to 38 HP
Maxes top-discharge VRF
Top-discharge VRF for larger floors, from 8 HP to 38 HP. Ask us for the current outdoor model.
ACHX-B and ACHX-BVD (Helios) horizontal-screw machines on microchannel coils, AVX-A and AVX-B (Achelous) vertical screws, and ACDS (Zeus) scroll chillers. The AVX-B specification page covers the 100 TR to 400 TR sizes.
WCS scroll from 12 TR, WCHX-A (Hyperion) and WCFX-E / WCFX-V (Poseidon) screws, then the DCLC-M (Prometheus) oil-free magnetic-bearing and DCLC-D (Hercules) centrifugal machines up to 4000 TR for district-cooling scale plants.
Precision environmental control for server rooms and equipment rooms, in chilled water, direct expansion or dual coil, with optional VFD compressors and EC fans.
Chilled water, DX or dual coil
VFD compressor and EC fan options
High-ambient capable
Ideal applicationServer rooms, control rooms, telecom and equipment rooms
Proprietary engineering
Key Dunham-Bush breakthroughs
The engineering features that give Dunham-Bush superior seasonal efficiency, long compressor life and whisper-quiet acoustics.
Magnetic bearing
Oil-free magnetic bearing compressors
The Prometheus (DCLC-M / WCM) and Athena (ACM-AE) chillers run inverter-driven dual-stage compressors on magnetic bearings — no oil circuit, no oil changes, and high IPLV at part load.
Flooded evaporator
Flooded shell-and-tube evaporators
Dunham-Bush pioneered flooded heat exchange. Integral finned copper tubes sit submerged in refrigerant, with cleanable tubes and removable water heads for service.
Screw compressor
Helical screw compressors with sliding-valve control
Semi-hermetic horizontal and vertical screws with infinite capacity control down to 12.5% of unit capacity, suction gas-cooled motors and no external oil pump.
Microchannel
Microchannel V-coil condensers, TCP coated
All-aluminium microchannel coils with brazed louvered fin in a V arrangement, finished with a TCP anti-corrosion layer for coastal and industrial air.
Vision 2020i
Vision 2020i touchscreen controller
Automatic staging, predictive diagnostic alarms, trending and BACnet/ModBus integration, extended by Chiller Plant Manager and Chiller 2 Cloud for whole-plant supervision.
VRF-6Pro
VRF-6Pro control stack
SmartLink arbitrary-topology wiring, an IP55 EnvironBox control enclosure, HyperSensor virtual-sensor backup and BTConnect Bluetooth commissioning on the ACE and MAXes outdoors.
Low GWP
Low-GWP and green plant options
R513A, R1234ze and R1233zd(E) on the centrifugal range, plus ice thermal storage, heat recovery and geothermal heat-pump systems.
Installation excellence
Sri Engineering Works installation standards for Dunham-Bush
Hydronic loop design
Pipe sizing, pump head calculation and balancing-valve installation.
Vibration and acoustic control
Spring isolator mounts and inertia pads so plant noise stays out of the building.
Chemical tube descaling
Routine condenser bundle descaling to hold the design approach temperature.
Commissioning records
Charge by weight, pressure and vacuum test logs, and a signed commissioning report at handover.
Standards
Dunham-Bush equipment, as the catalogues state it
Every figure in the sections below is taken from a published Dunham-Bush catalogue. These are the standards and ratings those catalogues are measured against.
AHRI 550/590Chiller performance certified, with Dunham-Bush's own AHRI-witnessed test facility
ASHRAE 90.1ACHX-B air-cooled screw meets the 2016 efficiency tables
ASMECertified pressurised-vessel line for shells and heat exchangers
ISO 9001:2015Dunham-Bush Industries Sdn Bhd quality management
ETLElectrical safety listing on the packaged range
BEE star ratedComfortline cassettes, towers and ductables rated to IS 1391 (Part 2) 2023
Plant room
Dunham-Bush chiller selector, 10 TR to 4000 TR
Every Dunham-Bush chiller family carries a series code and a project name. Use the table to find the family that matches your plant load, then ask us for an AHRI-certified selection against your actual chilled-water temperatures, ambient and fouling factor — the catalogue figures below are nominal.
Dunham-Bush chiller series, capacity, compressor type, refrigerant and typical application
Series
Capacity
Type
Compressor
Refrigerant
Typical application
DCLC-D / DCLC-DYHercules
300 – 3000 TR (1055 – 10550 kW)
Centrifugal chiller
Dual-stage centrifugal, VFD optional
R134a · R513A · R1233zd(E)
Airports, high-rise towers, district cooling, metro plants
DCLC-M / WCMPrometheus
75 – 1200 TR (264 – 4220 kW)
Magnetic bearing chiller
Oil-free magnetic bearing, inverter dual-stage
R134a · R513A · R1234ze
Data centres, green-rated offices, low-noise retrofitsOil-free: no oil management, no annual oil change, high IPLV
ACM-AEAthena
81 – 540 TR (285 – 1899 kW)
Air-cooled magnetic bearing chiller
Oil-free magnetic bearing, inverter dual-stage
R134a · R513A · R1234ze
Sites with no cooling tower and a tight sound limit
WCFX-EPoseidon
60 – 1000 TR (211 – 3517 kW)
Water-cooled screw chiller
Vertical screw, flooded shell & tube
R134a · R513A
Hospitals, campuses, pharma plants, malls
WCFX-V (VFD)Poseidon
130 – 750 TR (457 – 2638 kW)
Water-cooled screw chiller, inverter
Inverter-driven vertical screw
R134a
Plants that run long hours at part load
WCHX-AHyperion
85 – 510 TR (300 – 1795 kW)
Water-cooled screw chiller
Semi-hermetic screw, VFD option
R134a
Compact plant rooms, industrial process coolingCatalogue best point 0.577 kW/TR, COP 6.09 at AHRI standard conditions
WCSProteus
12 – 62 TR (42 – 218 kW)
Water-cooled scroll chiller
Multiple scroll, patented shell & tube
R407C
Small plants, process chilling, standby duty
AVX-AAchelous
96 – 548 TR (338 – 1929 kW)
Air-cooled screw chiller
Vertical screw, flooded evaporator
R134a
High-ambient sites, IT parks, industrial sheds
AVX-B (VFD)Achelous
115 – 470 TR (406 – 1656 kW)
Air-cooled screw chiller, inverter
Inverter-driven vertical screw
R134a
Part-load heavy loads with a low-noise requirement
Vision 2020i controllerTouchscreen chiller controller on the ACHX and AVX ranges: automatic staging, predictive alarms, trending and BMS integration.
Chiller Plant Manager (CPM)Supervises every machine in the plant room — chillers, pumps, cooling towers — and sequences them against the real load.
Chiller 2 Cloud (C2C)Remote monitoring over BACnet, ModBus or the internet, with NetVisorPRO data and history logging and graphical animation.
Green plant optionsIce thermal storage, heat-recovery systems, geothermal heat pumps and next-generation HFO refrigerants for low-GWP plants.
VRF-6Pro platform
Six control technologies inside every ACE and MAXes outdoor unit
The DB VRF-6Pro outdoor platform (ACE side-discharge and MAXes top-discharge) runs six named control technologies. They are the reason a VRF-6Pro system keeps commissioning simple on site and stays diagnosable afterwards.
01
SmartLink
Arbitrary-topology communication wiring — the control bus does not have to follow a fixed daisy chain, which cuts rework on retrofit floors.
02
EnvironBox
IP55 fully enclosed control box, so the electronics survive coastal air, dust and washdown on an open terrace.
03
HyperSensor
A complete sensor set with virtual-sensor backup: the system keeps running on a modelled value if a physical sensor fails.
04
EnergyWise
Upgraded part-load logic that holds efficiency when only a few indoor units are calling.
05
AirEase
Comfort-side control — steadier room temperature and gentler airflow changes at low load.
06
BTConnect
Bluetooth and cloud commissioning platform, so settings and fault history are read from a phone at the outdoor unit.
DB Smart Mini VRF outdoor1.2 – 6.3 HP · 3.6 – 18 kW, 1 to 9 indoor units, single phase
Connectable indoor units
4-way cassette2.8 – 18.0 kW
Compact 4-way cassette1.5 – 6.3 kW
2-way cassette2.2 – 7.1 kW
1-way cassette1.8 – 7.1 kW
Low static duct1.5 – 11.2 kW
Mid static duct1.5 – 16.0 kW
High static duct5.6 – 56.0 kW
Hi-wall1.5 – 8.0 kW
Floor standing (concealed / exposed)2.2 – 8.0 kW
Ceiling & floor22.0 – 56.0 kW
Fresh air processing unit18.0 – 40.0 kW
Airside
Air handlers, fan walls and fan coils on the same chilled-water loop
The chilled-water side is only half a plant. Dunham-Bush builds the air handlers, fan walls, blowers and fan coils that sit on it, so one supplier covers the plant room and the ceiling void.
ECS3 / ESCS3
Central station air handling units
1,000 – 56,000 CFM (1,700 – 95,000 m³/h)
Double skin with PU insulation, extruded aluminium profile, multizone capable, AHRI certified.
CRAH
Fan wall units
29,430 – 58,860 CFM (50,000 – 100,000 m³/h)
EC-fan array with advanced controller and pressure independent balancing control valve (PIBCV).
VCB / HCB
Chilled water air handling units
3,100 – 18,700 CFM (5,266 – 31,780 m³/h)
Heavy-gauge steel, epoxy powder-coated casing, optional hot water coils, heaters and hydrophilic fins.
CC
Horizontal blower units
200 – 4,000 CFM (340 – 6,796 m³/h)
High-static application, belt driven with adjustable pulley, low-noise blowers.
CR
Fan coil units
100 – 1,940 CFM (176 – 3,300 m³/h)
Ducted, ceiling exposed, floor standing, cassette and wall mounted, with plenum box for return air.
DB-Aire
Precision environmental control
2 – 32 TR (7 – 110 kW)
Chilled water, direct expansion or dual coil, optional VFD compressors and EC fan, for server and equipment rooms.
Reference projects
Where Dunham-Bush plant already runs
Dunham-Bush plant is installed in buildings most people have heard of. These are the manufacturer's own reference projects — we quote them because they show what the equipment is specified for, not because Sri Engineering Works executed them.
India
Parliament House, New Delhi3 × DCLCDV600 and 5 × DCLCV800 centrifugal chillers
Vijayawada International AirportWCFX-E 40T × 3 water-cooled screw chillers
Goa Mopa International Airport3 × DCLCDV700E and 4 × DCLCDV1000E
AIIMS Rajkot5 × DCLCDV1000E centrifugal chillers
Yashoda Hospital, HyderabadWCF50TV and WCFX60T
Lucknow High Court4 × WCFX41
IIM Bodh Gaya4 × WCFX41
IIT Bhubaneswar campusWCFX46
Tata Steel, Jamshedpur & Kalinganagar41 AC packages, AHUs, 37 × WCFX (270–500 TR) and 7 × DCLC1250
Delhi, Chennai, Mumbai, Ahmedabad and Pune MetroAround 160 chillers across the Indian metro programme
Bombay House, Mumbai (IGBC Platinum)2 × DCLCM 100 TR and 2 × DCLCM 200 TR with fan coil units
Worldwide
Petronas Twin Towers, Kuala LumpurMalaysia
Marina Bay Sands, SingaporeSingapore
The London EyeUnited Kingdom
Beijing National Stadium (Bird's Nest)China
NASA Space Center Houston & Kennedy Space CenterUnited States
London Heathrow, Beijing and Doha International AirportsUK · China · Qatar
Riyadh Metro and Qatar Gold Line MetroSaudi Arabia · Qatar
Rooppur and Belarusian nuclear power plantsBangladesh · Belarus
IBM Hursley data centreUnited Kingdom
Al Dana Tower, QatarQatar
Dunham-Bush in India
Dunham-Bush sells in India through DB Aire India Pvt Ltd. The India line-up is narrower than the global catalogue and is what we quote from day to day.
50+ sales and service dealers and 2 authorised stockists appointed in the last six months
6 DB Experience Centres inaugurated, 3 more in progress — ours is the Visakhapatnam centre
Over 2000 HP of VRF, 1000 TR of cassettes and 350 TR of duct-free super floor standing units running in India
India's first 8.5 TR duct-free tower, in both cooling-only and heat-pump versions
Enrolled as an approved HVAC brand at GMR, Delhi University, IIT Indore and DPS
Dunham-Bush questions
Dunham-Bush HVAC questions
Dunham-Bush Experience Centre is at Door No. 58-1-303, SRS Plaza, Ground Floor, Butchirajupalem, near NAD Junction, Visakhapatnam, Andhra Pradesh. It is a separate address from the NAD Flyover office. Call 0891-2595288 to arrange a visit, or use the quote form on this page.