🇺🇸 USA · Est. 1894Authorised dealer

Dunham-Bush HVAC

Cassettes, towers, ductables, Mini VRF and industrial chillers

Dunham-Bush builds Comfortline cassettes, towers and ductables, DB Smart Mini VRF, the VRF-6Pro ACE and MAXes platform, floor-standing units, rooftop packages, and an AHRI-certified chiller range that runs from a 10 TR scroll machine to a 3000 TR centrifugal. Sri Engineering Works supplies, installs and services that whole range across Andhra Pradesh and Telangana — a single cabin, a hotel floor, or a central plant room.

Official Dunham-Bush portal
Engineering heritage130+ YearsFounded in the USA, 1894
Chiller capacity12 to 4000 TRScroll, screw and centrifugal
Light commercialFrom 1 TRCassette, duct, tower and VRF
Installed in India2000+ HP VRFPlus 1000 TR of cassettes
Reception desk and illuminated Dunham-Bush wall at the Visakhapatnam Experience Centre
DB Smart cassette, duct and hi-wall displays on the showroom wall
Dunham-Bush floor-standing units beside a seating table in the showroom
Wide view of the DB Smart wall and product display screens
History, milestones and Smart product-lineup boards in the showroom

Dunham-Bush Experience Centre

The light-commercial and VRF range can be seen here in person: cassettes, ductables, hi-wall units and floor-standing machines.

Door No. 58-1-303SRS Plaza, Ground FloorButchirajupalem, near NAD JunctionVisakhapatnam, Andhra Pradesh0891-2595288
Equipment portfolio

Dunham-Bush product range & series

The complete lineup of Dunham-Bush equipment, supplied with official manufacturer warranty and expert installation.

Cassette AC1.5 TR to 4 TR

Comfortline 4-way cassette

Fixed-speed and inverter 4-way cassettes on R-32. Each model below has its own specification page, from the 1.5 TR inverter to the 4 TR three-phase fixed-speed unit.

  • R-32
  • Fixed speed and inverter
  • Up to 48°C ambient
Ideal applicationOffices, meeting rooms, hotels, restaurants, showrooms, clinics
VRF / VRV System1.2 HP to 6.3 HP

DB Smart Mini VRF outdoor

Single-phase Mini VRF outdoors from 3.5 kW to 17.5 kW cooling. They accept hi-wall, mid-static duct, 1-way cassette and 4-way cassette indoors. A multi-indoor system uses these same indoor and outdoor models.

  • 1 to 9 indoors
  • R410A
  • −15°C to 55°C cooling
Ideal application1 to 9 indoor units
Split AC1 TR, 1.5 TR and 2 TR

RAC splits

Room splits in inverter and non-inverter, cooling only and heat pump, at 1 TR, 1.5 TR and 2 TR. Ask us for the current model and a site quotation.

  • Inverter and non-inverter
  • Cooling only and heat pump
  • 1, 1.5 and 2 TR
Ideal applicationHomes, cabins, small shops
VRF / VRV System7.2 HP to 16 HP

ACE side-discharge VRF

Side-discharge VRF from 7.2 HP to 16 HP. Indoor options include hi-wall, 4-way cassette, 2-way cassette, 1-way cassette, ducted, floor ceiling, fresh air and treated fresh air. Ask us for the current outdoor model.

  • 7.2 HP to 16 HP
  • 2-way cassette
  • Treated fresh air
Ideal applicationSide-discharge VRF, 7.2 HP to 16 HP
VRF / VRV System8 HP to 38 HP

Maxes top-discharge VRF

Top-discharge VRF for larger floors, from 8 HP to 38 HP. Ask us for the current outdoor model.

  • 8 HP to 38 HP
  • Top discharge
Ideal applicationHotels, offices, larger commercial buildings
Packaged AC2.6 TR to 146 TR

Rooftop units

Packaged rooftop units from 2.6 TR to 146 TR. Ask us for the current model and a site quotation.

  • 2.6 TR to 146 TR
  • Packaged rooftop
Ideal applicationRetail floors, halls, industrial sheds
Air-Cooled Packaged Chiller10 TR to 590 TR

Air-cooled chillers — Helios, Achelous and Zeus

ACHX-B and ACHX-BVD (Helios) horizontal-screw machines on microchannel coils, AVX-A and AVX-B (Achelous) vertical screws, and ACDS (Zeus) scroll chillers. The AVX-B specification page covers the 100 TR to 400 TR sizes.

  • Screw and scroll
  • 10 TR to 590 TR
  • Microchannel TCP-coated coils
  • AHRI 550/590 certified
Models in this series
Ideal applicationIT parks, malls, hospitals, industrial plants
Water-Cooled Central Chiller12 TR to 4000 TR

Water-cooled and centrifugal chillers

WCS scroll from 12 TR, WCHX-A (Hyperion) and WCFX-E / WCFX-V (Poseidon) screws, then the DCLC-M (Prometheus) oil-free magnetic-bearing and DCLC-D (Hercules) centrifugal machines up to 4000 TR for district-cooling scale plants.

  • 12 TR to 4000 TR
  • Oil-free magnetic bearing option
  • R513A / R1234ze / R1233zd(E)
Ideal applicationData centres, pharmaceutical factories, high-rise towers
Air Handling & Cleanroom100 CFM to 58,860 CFM

Air handling units, fan walls and fan coils

ECS3 / ESCS3 central-station AHUs (1,000–56,000 CFM), CRAH EC-fan walls (29,430–58,860 CFM), VCB / HCB chilled-water AHUs, CC horizontal blowers and CR fan coil units — double skin with PU insulation, AHRI certified.

  • Double skin PU panels
  • EC fan wall with PIBCV
  • Optional hot water coils and hydrophilic fins
Ideal applicationPharma labs, hospital operation theatres, cleanrooms
Precision Cooling2 TR to 32 TR

DB-Aire precision air conditioning

Precision environmental control for server rooms and equipment rooms, in chilled water, direct expansion or dual coil, with optional VFD compressors and EC fans.

  • Chilled water, DX or dual coil
  • VFD compressor and EC fan options
  • High-ambient capable
Ideal applicationServer rooms, control rooms, telecom and equipment rooms
Proprietary engineering

Key Dunham-Bush breakthroughs

The engineering features that give Dunham-Bush superior seasonal efficiency, long compressor life and whisper-quiet acoustics.

Magnetic bearing

Oil-free magnetic bearing compressors

The Prometheus (DCLC-M / WCM) and Athena (ACM-AE) chillers run inverter-driven dual-stage compressors on magnetic bearings — no oil circuit, no oil changes, and high IPLV at part load.

Flooded evaporator

Flooded shell-and-tube evaporators

Dunham-Bush pioneered flooded heat exchange. Integral finned copper tubes sit submerged in refrigerant, with cleanable tubes and removable water heads for service.

Screw compressor

Helical screw compressors with sliding-valve control

Semi-hermetic horizontal and vertical screws with infinite capacity control down to 12.5% of unit capacity, suction gas-cooled motors and no external oil pump.

Microchannel

Microchannel V-coil condensers, TCP coated

All-aluminium microchannel coils with brazed louvered fin in a V arrangement, finished with a TCP anti-corrosion layer for coastal and industrial air.

Vision 2020i

Vision 2020i touchscreen controller

Automatic staging, predictive diagnostic alarms, trending and BACnet/ModBus integration, extended by Chiller Plant Manager and Chiller 2 Cloud for whole-plant supervision.

VRF-6Pro

VRF-6Pro control stack

SmartLink arbitrary-topology wiring, an IP55 EnvironBox control enclosure, HyperSensor virtual-sensor backup and BTConnect Bluetooth commissioning on the ACE and MAXes outdoors.

Low GWP

Low-GWP and green plant options

R513A, R1234ze and R1233zd(E) on the centrifugal range, plus ice thermal storage, heat recovery and geothermal heat-pump systems.

Installation excellence

Sri Engineering Works installation standards for Dunham-Bush

Hydronic loop design

Pipe sizing, pump head calculation and balancing-valve installation.

Vibration and acoustic control

Spring isolator mounts and inertia pads so plant noise stays out of the building.

Chemical tube descaling

Routine condenser bundle descaling to hold the design approach temperature.

Commissioning records

Charge by weight, pressure and vacuum test logs, and a signed commissioning report at handover.

Standards

Dunham-Bush equipment, as the catalogues state it

Every figure in the sections below is taken from a published Dunham-Bush catalogue. These are the standards and ratings those catalogues are measured against.

  • AHRI 550/590Chiller performance certified, with Dunham-Bush's own AHRI-witnessed test facility
  • ASHRAE 90.1ACHX-B air-cooled screw meets the 2016 efficiency tables
  • ASMECertified pressurised-vessel line for shells and heat exchangers
  • ISO 9001:2015Dunham-Bush Industries Sdn Bhd quality management
  • ETLElectrical safety listing on the packaged range
  • BEE star ratedComfortline cassettes, towers and ductables rated to IS 1391 (Part 2) 2023
Plant room

Dunham-Bush chiller selector, 10 TR to 4000 TR

Every Dunham-Bush chiller family carries a series code and a project name. Use the table to find the family that matches your plant load, then ask us for an AHRI-certified selection against your actual chilled-water temperatures, ambient and fouling factor — the catalogue figures below are nominal.

Dunham-Bush chiller series, capacity, compressor type, refrigerant and typical application
SeriesCapacityTypeCompressorRefrigerantTypical application
DCLC-D / DCLC-DYHercules300 – 3000 TR (1055 – 10550 kW)Centrifugal chillerDual-stage centrifugal, VFD optionalR134a · R513A · R1233zd(E)Airports, high-rise towers, district cooling, metro plants
DCLC-M / WCMPrometheus75 – 1200 TR (264 – 4220 kW)Magnetic bearing chillerOil-free magnetic bearing, inverter dual-stageR134a · R513A · R1234zeData centres, green-rated offices, low-noise retrofitsOil-free: no oil management, no annual oil change, high IPLV
ACM-AEAthena81 – 540 TR (285 – 1899 kW)Air-cooled magnetic bearing chillerOil-free magnetic bearing, inverter dual-stageR134a · R513A · R1234zeSites with no cooling tower and a tight sound limit
WCFX-EPoseidon60 – 1000 TR (211 – 3517 kW)Water-cooled screw chillerVertical screw, flooded shell & tubeR134a · R513AHospitals, campuses, pharma plants, malls
WCFX-V (VFD)Poseidon130 – 750 TR (457 – 2638 kW)Water-cooled screw chiller, inverterInverter-driven vertical screwR134aPlants that run long hours at part load
WCHX-AHyperion85 – 510 TR (300 – 1795 kW)Water-cooled screw chillerSemi-hermetic screw, VFD optionR134aCompact plant rooms, industrial process coolingCatalogue best point 0.577 kW/TR, COP 6.09 at AHRI standard conditions
WCSProteus12 – 62 TR (42 – 218 kW)Water-cooled scroll chillerMultiple scroll, patented shell & tubeR407CSmall plants, process chilling, standby duty
AVX-AAchelous96 – 548 TR (338 – 1929 kW)Air-cooled screw chillerVertical screw, flooded evaporatorR134aHigh-ambient sites, IT parks, industrial sheds
AVX-B (VFD)Achelous115 – 470 TR (406 – 1656 kW)Air-cooled screw chiller, inverterInverter-driven vertical screwR134aPart-load heavy loads with a low-noise requirement
ACHX-B / ACHX-BVDHelios90 – 590 TR (315 – 2073 kW)Air-cooled screw chillerHorizontal screw; BVD is inverter-drivenR134aRooftop plants, malls, hospitals, manufacturingMicrochannel V-coil with TCP anti-corrosion coating; operates 7–46°C ambient
ACDSZeus10 – 146 TR (35 – 512 kW)Air-cooled scroll chillerMultiple scroll, plate heat exchangerR410ASmaller buildings, modular and staged plants

Heat pump range

  • WCFX-HPScrew heat pump — cooling 55–586 TR, heating 68–712 TR, R134a
  • WCS-HPScroll heat pump — 11–70 TR, R134a / R407C
  • ACX(HR)-RAir-cooled screw heat pump — 95–450 TR cooling and heating, R134a
  • ACDS(HP)-HAir-cooled scroll heat pump — 18–40 TR cooling, 20–40 TR heating, R410A

Plant controls & green options

  • Vision 2020i controllerTouchscreen chiller controller on the ACHX and AVX ranges: automatic staging, predictive alarms, trending and BMS integration.
  • Chiller Plant Manager (CPM)Supervises every machine in the plant room — chillers, pumps, cooling towers — and sequences them against the real load.
  • Chiller 2 Cloud (C2C)Remote monitoring over BACnet, ModBus or the internet, with NetVisorPRO data and history logging and graphical animation.
  • Green plant optionsIce thermal storage, heat-recovery systems, geothermal heat pumps and next-generation HFO refrigerants for low-GWP plants.
VRF-6Pro platform

Six control technologies inside every ACE and MAXes outdoor unit

The DB VRF-6Pro outdoor platform (ACE side-discharge and MAXes top-discharge) runs six named control technologies. They are the reason a VRF-6Pro system keeps commissioning simple on site and stays diagnosable afterwards.

SmartLink

Arbitrary-topology communication wiring — the control bus does not have to follow a fixed daisy chain, which cuts rework on retrofit floors.

EnvironBox

IP55 fully enclosed control box, so the electronics survive coastal air, dust and washdown on an open terrace.

HyperSensor

A complete sensor set with virtual-sensor backup: the system keeps running on a modelled value if a physical sensor fails.

EnergyWise

Upgraded part-load logic that holds efficiency when only a few indoor units are calling.

AirEase

Comfort-side control — steadier room temperature and gentler airflow changes at low load.

BTConnect

Bluetooth and cloud commissioning platform, so settings and fault history are read from a phone at the outdoor unit.

Outdoor units

  • ACE outdoor (side discharge)7.2 – 16 HP · cooling 20.0 – 28.0 kW, heat pump 25.2 – 67.0 kW
  • MAXes outdoor (top discharge)8 – 38 HP · cooling 22.4 – 255.0 kW, heat pump 25.2 – 318.0 kW
  • DB Smart Mini VRF outdoor1.2 – 6.3 HP · 3.6 – 18 kW, 1 to 9 indoor units, single phase

Connectable indoor units

  • 4-way cassette2.8 – 18.0 kW
  • Compact 4-way cassette1.5 – 6.3 kW
  • 2-way cassette2.2 – 7.1 kW
  • 1-way cassette1.8 – 7.1 kW
  • Low static duct1.5 – 11.2 kW
  • Mid static duct1.5 – 16.0 kW
  • High static duct5.6 – 56.0 kW
  • Hi-wall1.5 – 8.0 kW
  • Floor standing (concealed / exposed)2.2 – 8.0 kW
  • Ceiling & floor22.0 – 56.0 kW
  • Fresh air processing unit18.0 – 40.0 kW
Airside

Air handlers, fan walls and fan coils on the same chilled-water loop

The chilled-water side is only half a plant. Dunham-Bush builds the air handlers, fan walls, blowers and fan coils that sit on it, so one supplier covers the plant room and the ceiling void.

ECS3 / ESCS3

Central station air handling units

1,000 – 56,000 CFM (1,700 – 95,000 m³/h)

Double skin with PU insulation, extruded aluminium profile, multizone capable, AHRI certified.

CRAH

Fan wall units

29,430 – 58,860 CFM (50,000 – 100,000 m³/h)

EC-fan array with advanced controller and pressure independent balancing control valve (PIBCV).

VCB / HCB

Chilled water air handling units

3,100 – 18,700 CFM (5,266 – 31,780 m³/h)

Heavy-gauge steel, epoxy powder-coated casing, optional hot water coils, heaters and hydrophilic fins.

CC

Horizontal blower units

200 – 4,000 CFM (340 – 6,796 m³/h)

High-static application, belt driven with adjustable pulley, low-noise blowers.

CR

Fan coil units

100 – 1,940 CFM (176 – 3,300 m³/h)

Ducted, ceiling exposed, floor standing, cassette and wall mounted, with plenum box for return air.

DB-Aire

Precision environmental control

2 – 32 TR (7 – 110 kW)

Chilled water, direct expansion or dual coil, optional VFD compressors and EC fan, for server and equipment rooms.

Reference projects

Where Dunham-Bush plant already runs

Dunham-Bush plant is installed in buildings most people have heard of. These are the manufacturer's own reference projects — we quote them because they show what the equipment is specified for, not because Sri Engineering Works executed them.

India

  • Parliament House, New Delhi3 × DCLCDV600 and 5 × DCLCV800 centrifugal chillers
  • Vijayawada International AirportWCFX-E 40T × 3 water-cooled screw chillers
  • Goa Mopa International Airport3 × DCLCDV700E and 4 × DCLCDV1000E
  • AIIMS Rajkot5 × DCLCDV1000E centrifugal chillers
  • Yashoda Hospital, HyderabadWCF50TV and WCFX60T
  • Lucknow High Court4 × WCFX41
  • IIM Bodh Gaya4 × WCFX41
  • IIT Bhubaneswar campusWCFX46
  • Tata Steel, Jamshedpur & Kalinganagar41 AC packages, AHUs, 37 × WCFX (270–500 TR) and 7 × DCLC1250
  • Delhi, Chennai, Mumbai, Ahmedabad and Pune MetroAround 160 chillers across the Indian metro programme
  • Bombay House, Mumbai (IGBC Platinum)2 × DCLCM 100 TR and 2 × DCLCM 200 TR with fan coil units

Worldwide

  • Petronas Twin Towers, Kuala LumpurMalaysia
  • Marina Bay Sands, SingaporeSingapore
  • The London EyeUnited Kingdom
  • Beijing National Stadium (Bird's Nest)China
  • NASA Space Center Houston & Kennedy Space CenterUnited States
  • London Heathrow, Beijing and Doha International AirportsUK · China · Qatar
  • Riyadh Metro and Qatar Gold Line MetroSaudi Arabia · Qatar
  • Rooppur and Belarusian nuclear power plantsBangladesh · Belarus
  • IBM Hursley data centreUnited Kingdom
  • Al Dana Tower, QatarQatar

Dunham-Bush in India

Dunham-Bush sells in India through DB Aire India Pvt Ltd. The India line-up is narrower than the global catalogue and is what we quote from day to day.

  • 50+ sales and service dealers and 2 authorised stockists appointed in the last six months
  • 6 DB Experience Centres inaugurated, 3 more in progress — ours is the Visakhapatnam centre
  • Over 2000 HP of VRF, 1000 TR of cassettes and 350 TR of duct-free super floor standing units running in India
  • India's first 8.5 TR duct-free tower, in both cooling-only and heat-pump versions
  • Enrolled as an approved HVAC brand at GMR, Delhi University, IIT Indore and DPS
Dunham-Bush questions

Dunham-Bush HVAC questions

Dunham-Bush Experience Centre is at Door No. 58-1-303, SRS Plaza, Ground Floor, Butchirajupalem, near NAD Junction, Visakhapatnam, Andhra Pradesh. It is a separate address from the NAD Flyover office. Call 0891-2595288 to arrange a visit, or use the quote form on this page.

Explore related: AC repair · AMC plans · all model numbers · all brands