Ductable AC & Air Handling Units
Concealed cooling for large open floors — only elegant grilles and slot diffusers stay visible.
View service
One outdoor deck, dozens of independently controlled zones — engineered for multi-floor commercial buildings.
VRF (Variable Refrigerant Flow) — called VRV by Daikin — connects many indoor units to a single modular outdoor system. Inverter scroll compressors and electronic expansion valves vary the refrigerant sent to each indoor unit, so every room gets exactly the cooling it needs and nothing more.
The result is precise zone-by-zone temperature control, dramatically lower part-load power consumption, and a clean building façade with just one condenser deck on the roof. It is the default choice for modern retail stores, corporate floors and premium residences.
Our engineers size every system with the OEM's own selection software, lay out Refnet joints and header branches in CAD, and hand over with a full commissioning report signed jointly with the brand's factory engineer.

Each cabin, store section or apartment runs its own set-point and schedule from a wall controller or central touchscreen.
3-pipe systems move heat from zones that need cooling to zones that need heating, for near-free simultaneous operation.
BACnet and Modbus gateways connect the whole system to your building management platform for monitoring and alarms.
Power-proportional distribution meters split consumption between tenants in shared commercial buildings.
Modular outdoor units combine up to 120 TR on a single rooftop deck — no plant room required.
All joints are brazed under continuous dry nitrogen purge to prevent oxidation scale inside the pipework.
| Capacity range | 3 TR to 120 TR modular combinations |
|---|---|
| Energy rating | ISEER up to 5.2 |
| Refrigerant | R-410A / R-32 |
| Piping length | Up to 1,000 m total, 165 m actual |
| Level difference | Up to 90 m between outdoor and indoor |
| Controls | Wired, wireless, central touchscreen, BMS |
| Pressure test | 600 PSI (41.3 bar) held for 24 hours |
| Warranty | Up to 5 years on compressor (OEM) |
Room-by-room load calculation considering orientation, glazing, occupancy and equipment.
Outdoor module selection, indoor unit mapping, Refnet sizing and CAD piping layout.
Hard-drawn copper routed on supports, brazed under nitrogen purge and insulated.
24-hour 600 PSI hold test, then triple evacuation below 500 microns.
Refrigerant top-up by weight, addressing, test run and joint OEM sign-off.