Choosing a system

Which commercial AC system suits your building?

Most commercial enquiries come down to four system types. The table is a starting point — we confirm the choice with a heat-load calculation and a site visit, because ceiling void depth, where the outdoor units can sit and how the building is zoned often decide it.

  • No ceiling void? A floor-standing tower or a super floor-standing unit throws air up to 50 feet without ductwork
  • Server or control room? DB-Aire precision units hold tighter temperature and humidity than comfort cooling
  • Pharma or medical? Cleanroom AHUs with HEPA filtration, built and validated to the room classification
Commercial air conditioning system types, typical capacity and where each one fits
SystemTypical capacityBest forWhy
Cassette AC1 – 5 TR per unitOffices, clinics, restaurants, showroomsFlush in the ceiling, no ductwork, each unit controlled on its own
Ductable AC & AHU3 – 20 TR per unitRetail floors, banquet halls, auditoriumsEven air throw across a large open floor, equipment hidden above the ceiling
VRF / VRV8 – 114 HP per outdoorMulti-floor offices, hotels, hospitals, mixed-useOne outdoor unit, many independently controlled rooms, best part-load efficiency
Chilled water plant10 – 4000 TRHospitals, factories, malls, data centresLowest cost per ton at scale, with redundancy and long plant life
By building type

What we usually specify, by the kind of site

Retail & showrooms

Ductable or cassette, with air curtains at the entrance and night-shift installation.

Offices

VRF with per-cabin control, or cassettes on a smaller floor plate.

Hotels & hospitality

VRF for guest rooms, ductable for lobbies and banquet halls.

Hospitals & clinics

Chilled water with AHUs, plus HEPA filtration for theatres.

Factories & plants

Chiller plants, packaged units and industrial ventilation.

Restaurants

Cassette or ductable sized for kitchen heat gain and high occupancy.

Scope

One contractor from heat load to handover

Commercial jobs go wrong at the joins — between the equipment supplier, the ducting contractor and the electrician. We carry all three, so there is one programme, one site team and one party responsible at handover.

  • Room-by-room heat-load calculation and equipment selection
  • CAD duct layout, CNC-cut GI duct fabrication and insulation
  • Copper piping brazed under dry nitrogen, pressure tested and evacuated
  • Power, control wiring and BMS integration where the building needs it
  • Measured air balancing to the design CFM, with a report
  • Commissioning records, warranty registration and an AMC handover
Brands

Commercial ranges we are authorised to supply

We quote model-wise against the current dealer price lists, and we will say when a cheaper model does the same job. Where a brand has an India-specific commercial range — Dunham-Bush's cassettes, towers and Mini VRF, or Daikin's VRV — those are the pages to read next.

Daikin

Splits, cassettes, ductables and VRV systems.

Dunham-Bush

Cassettes, ductables, VRF and chillers to 4000 TR.

All partner brands

Voltas, O General and Mitsubishi Electric.

Model directory

Specification pages for every model we list.

Where we work

Commercial AC across Andhra Pradesh and Telangana

Visakhapatnam is the main branch, at 58-22-50, NAD Flyover, APSEB Colony, NSTL, Visakhapatnam, Andhra Pradesh 530027, with stock and technicians in the city. Hyderabad and Vijayawada are branch offices. Site surveys in the three branch cities are usually scheduled within one to two working days; other cities are quoted the same way.

Visakhapatnam (Vizag)

Main branch, warehouse and local crews.

Tellapur, Hyderabad

AC service and installation in west Hyderabad.

Projects we have executed

Retail, industrial and commercial sites.

AMC plans

Preventive cover for commercial equipment.

Before you enquire

What makes a quote accurate

The more of this you can send, the closer the first quote is to the final number. If you have none of it, we survey the site instead — that visit is free in the branch cities.

  • Floor plan or room sizes, with ceiling heights
  • What each area is used for, and how many people are in it
  • Working hours, and whether cooling runs outside them
  • Where outdoor units can sit: terrace, rear setback or service shaft
  • Available power supply, single or three phase
  • Whether there is an existing system to replace or extend
FAQs

Common questions

Anything sized for a business rather than a bedroom: ceiling cassettes in an office or restaurant, ductable units and AHUs over a retail floor, a VRF system serving a whole building on one outdoor unit, or a chilled-water plant for a hospital or factory. We supply and install all four, and the right answer depends on floor area, ceiling void, how many zones need separate control and how many hours a day it runs.

Get a commercial AC quote

Send the floor plan or the room sizes and what the space is used for. We confirm site-survey requests within 24 hours, and quote the equipment and the installation together.