Cleanroom Ventilation & HEPA Filtration installation by Sri Engineering Works
ISO 14644 compliant · Validated

Cleanroom Ventilation & HEPA Filtration

Positive-pressure, HEPA-filtered air systems for operation theatres, pharma labs and electronics cleanrooms.

ISO 5–8
Cleanliness classes
99.995%
HEPA efficiency
60 ACPH
Air changes per hour
Overview

About Cleanroom & HEPA

Cleanrooms depend on the HVAC system for everything that matters — particle counts, pressure differentials, temperature and humidity. We design and build the complete air system to meet ISO 14644 and GMP requirements.

Dedicated AHUs with pre-, fine- and HEPA-filter stages feed terminal HEPA boxes in the ceiling. Room pressures are cascaded from the cleanest zone outward so contamination can never flow in.

Every installation is validated with DOP/PAO filter integrity tests, particle counts, airflow and recovery tests, with complete documentation for regulatory audits.

  • Audit-ready documentation for GMP and hospital accreditation
  • Consistent particle counts protect product quality and patients
  • Monitored pressures give early warning of filter or door issues
  • Energy-optimised air changes reduce running cost
Pharmaceutical cleanroom with ceiling HEPA terminals

At a glance

Cleanroom class
ISO Class 5 to ISO Class 8
Filtration
H14 HEPA, 99.995% @ 0.3 µm
Pressure cascade
+15 Pa to +30 Pa
Air changes
20 to 60 ACPH

Brands we install

Dunham-BushDaikinVoltas
Request a proposal
Key features

What's included

01

Pressure cascades

+15 Pa to +30 Pa differentials between zones, monitored with magnehelic gauges or sensors.

02

Terminal HEPA filtration

H13/H14 HEPA boxes with DOP ports for in-situ integrity testing.

03

Precision climate

Temperature within ±1 °C and humidity within ±5% RH using reheat and dehumidification.

04

Laminar airflow zones

LAF hoods and unidirectional flow ceilings over critical work areas.

05

Stainless & GI ducting

SS 304 ducts where required, with sealed, cleanable construction.

06

Complete validation

DQ, IQ, OQ and PQ documentation plus periodic re-validation support.

Specifications

Technical parameters

Cleanroom classISO Class 5 to ISO Class 8
FiltrationH14 HEPA, 99.995% @ 0.3 µm
Pressure cascade+15 Pa to +30 Pa
Air changes20 to 60 ACPH
Temperature±1 °C control band
Humidity±5% RH control band
Duct materialSS 304 / GI, sealed construction
ValidationDOP/PAO test, particle count, recovery
Applications

Where it's used

Hospital operation theatresPharmaceutical productionBiotech & research labsElectronics assemblyIVF & ICU suitesFood processing
Our process

How we deliver it

  1. 1

    URS review

    User requirement specification, room classes and process needs captured.

  2. 2

    Design qualification

    Air-change, pressure and filtration design documented for approval.

  3. 3

    Installation

    AHUs, ducts, HEPA terminals and controls installed to clean-build protocol.

  4. 4

    IQ / OQ

    Installation and operational checks, filter integrity and airflow tests.

  5. 5

    PQ & handover

    Performance qualification, particle counts and final validation dossier.

FAQs

Cleanroom & HEPA questions

We design and install ISO Class 5 to Class 8 cleanrooms, including hospital operation theatres to NABH guidelines.