Chilled Water Plants & Industrial Chillers installation by Sri Engineering Works
Heavy duty · 50 TR to 1,000+ TR

Chilled Water Plants & Industrial Chillers

Turnkey central plant rooms for hospitals, factories and IT parks — engineered for 24×7 reliability.

1,000+ TR
Central plant capacity
0.55
kW/TR plant efficiency
24×7
Critical-duty operation
Overview

About Chillers & Plants

Chilled-water systems produce cold water at a central plant and pump it to AHUs and fan-coil units throughout the building. They are the most efficient and controllable option for large, continuously operated facilities.

We deliver complete plant rooms: chillers, primary and secondary pump skids with VFDs, cooling towers, expansion tanks, Schedule-40 MS piping, headers, motorised valves, instrumentation and PLC-based controls.

Hydronic balancing, vibration isolation and high-quality insulation with aluminium or SS cladding ensure the plant runs quietly and efficiently for decades.

  • Lowest running cost per ton for large, continuous loads
  • Central equipment keeps noise and maintenance out of occupied areas
  • Scales easily as the facility grows
  • Precise humidity and temperature control for process cooling
Water-cooled chiller with insulated chilled-water headers

At a glance

Plant capacity
50 TR to 1,000+ TR
Chiller type
Air-/water-cooled, screw or scroll
Piping
Schedule-40 MS, welded & flanged
Pumping
Primary/secondary with VFD skids

Brands we install

Dunham-BushVoltasDaikin
Request a proposal
Key features

What's included

01

Air- & water-cooled options

Air-cooled for simpler installations; water-cooled with cooling towers for the best efficiency at scale.

02

Variable primary pumping

VFD-driven pumps match water flow to load, cutting pumping energy substantially.

03

Plant automation

PLC sequencing of chillers, pumps and towers with BMS telemetry and alarm logging.

04

Redundancy design

N+1 chillers and standby pumps keep critical facilities running during maintenance.

05

Hydronic balancing

Balancing valves set and verified so every AHU gets its design flow.

06

Vibration & acoustics

Spring isolators, inertia bases and flexible connectors protect structures and occupants.

Specifications

Technical parameters

Plant capacity50 TR to 1,000+ TR
Chiller typeAir-/water-cooled, screw or scroll
PipingSchedule-40 MS, welded & flanged
PumpingPrimary/secondary with VFD skids
Heat rejectionFRP cooling towers / air-cooled coils
ControlsPLC panel with BMS integration
InsulationNitrile / PUF with Al or SS cladding
Efficiency target≈ 0.55 kW/TR plant
Applications

Where it's used

Pharmaceutical plantsHospitals (500+ beds)IT parks & data hallsIndustrial process coolingMalls & multiplexesHotels & convention centres
Our process

How we deliver it

  1. 1

    Load & plant study

    Diversity-based load profile, redundancy needs and plant-room sizing.

  2. 2

    Plant design

    Chiller selection, pump heads, pipe sizing and P&ID drawings.

  3. 3

    Erection

    Equipment rigging, header fabrication, welding and hydro-testing.

  4. 4

    Controls & balancing

    PLC programming, sensor calibration and hydronic balancing.

  5. 5

    Commissioning

    Performance run with OEM engineers and complete O&M documentation.

FAQs

Chillers & Plants questions

Water-cooled chillers are more efficient but need cooling towers, water treatment and a plant room. Air-cooled chillers are simpler to install and maintain. We compare lifecycle cost for your site before recommending.