Ductable AC & Air Handling Units installation by Sri Engineering Works
High airflow · Architectural finish

Ductable AC & Air Handling Units

Concealed cooling for large open floors — only elegant grilles and slot diffusers stay visible.

8,500+
CFM per indoor unit
< 1.5%
Duct air leakage
250 Pa
High static pressure
Overview

About Ductable AC & AHU

Ductable air-conditioners hide the indoor unit above the false ceiling and distribute conditioned air through an insulated galvanised-iron duct network. Only grilles, linear slot diffusers and return air registers remain visible, keeping interiors clean and premium.

For larger spaces we deploy Air Handling Units with fresh-air intake, filtration banks and variable-speed fans, either with DX coils or connected to a chilled-water plant.

Every duct is sized for velocity and static pressure in AutoCAD, fabricated on CNC machines, acoustically lined where needed and balanced with an anemometer before handover.

  • Premium interiors with no visible wall-mounted units
  • Even temperatures across very large open floor plates
  • Fewer, larger machines are simpler to maintain than many splits
  • Easy to integrate fresh air, filtration and future BMS control
Supply duct runs with insulation above the false ceiling — Westside, Vijayawada

At a glance

Unit capacity
About 1 TR to 16.5 TR per indoor unit
Airflow
1,200 to 8,500+ CFM per unit
Duct material
24G / 22G / 20G galvanised iron
Insulation
Nitrile rubber / fibreglass

Brands we install

DaikinVoltasDunham-Bush
Request a proposal
Key features

What's included

01

Uniform air throw

Duct design distributes air evenly across large floors — no hot corners near glazing or entrances.

02

Invisible equipment

Units sit above the ceiling; interiors see only diffusers that match your lighting and ceiling layout.

03

Fresh-air & filtration

Treated fresh-air ducts and MERV/EU-grade filters improve indoor air quality in crowded spaces.

04

Acoustic treatment

Perforated acoustic lining and flexible connectors keep noise low in halls and offices.

05

Volume control dampers

VCDs on every branch allow fine airflow tuning during balancing and future layout changes.

06

Low-leakage fabrication

CNC-cut, pittsburgh-locked GI ducts with sealed joints keep leakage below 1.5%.

Specifications

Technical parameters

Unit capacityAbout 1 TR to 16.5 TR per indoor unit
Airflow1,200 to 8,500+ CFM per unit
Duct material24G / 22G / 20G galvanised iron
InsulationNitrile rubber / fibreglass
Static pressureUp to 250 Pa external
Acoustic liningPerforated GI with tissue foam
Air terminalsGrilles, linear slots, jet nozzles, 4-way diffusers
TestingAnemometer CFM & velocity balancing report
Applications

Where it's used

Showrooms & supermarketsBanquet & marriage hallsOpen-plan officesMultiplex & auditoriumsRestaurants & food courtsGyms & fitness studios
Our process

How we deliver it

  1. 1

    Site survey

    Ceiling void heights, structural beams and architect's reflected ceiling plan reviewed.

  2. 2

    Duct design

    CAD duct layout with velocity, static-pressure and diffuser throw calculations.

  3. 3

    Fabrication

    CNC-cut GI ducts fabricated, sealed and insulated off-site for speed and quality.

  4. 4

    Installation

    Units hung on isolators, ducts supported on threaded rods, drains graded and tested.

  5. 5

    Air balancing

    Every outlet measured and dampers set to the design CFM before handover.

FAQs

Ductable AC & AHU questions

Typically 450–600 mm for the unit and main duct. We check beam depths early and can route ducts or select low-height units to suit tight ceilings.