What you get

One outdoor unit, many independently controlled rooms

A VRV system replaces a row of split-AC condensers with a single inverter outdoor unit connected to many indoor units by shared refrigerant piping. Each room keeps its own set-point, and the compressor slows down when only a few rooms need cooling, which is where the energy saving comes from.

We handle the full job: heat-load calculation, outdoor-unit and indoor-unit selection, copper piping layout, brazing under nitrogen, pressure and vacuum testing, charging by weight, and a commissioning report.

  • Heat-load study room by room: orientation, glazing, occupancy and equipment
  • Mixed indoor units on one system: wall, cassette and ductable
  • Wired and wireless zone controllers, with BMS integration where the building needs it
  • Written commissioning report and AMC options at handover
Choosing a series

VRV IV-S for villas and small floors, modular VRV for larger buildings

The right size is set by the building's measured load, not by the number of rooms. We will say so if a ductable or cassette layout is cheaper for your space.

Figures follow our published Daikin model and brand pages. Final selection depends on your drawings and load.
VRV IV-S (compact)Modular VRV (larger)
Typical useVillas, small offices, single retail floorsMulti-floor offices, hospitals, malls, hotels
Outdoor capacity5 HP to 14 HP (RXQ5T / RXQ8T / RXQ10T on our model page)Modular combinations from 6 HP up to 64 HP
Indoor unitsUp to 14 per systemUp to 64 per system, depending on combination
RefrigerantR410A, factory chargedPer model: confirmed at quotation
Warranty on our model page1 year system + 5 years inverter scroll compressorConfirmed per model at quotation
How it runs

From drawings to handover

1. Site survey & load study

We measure or take off drawings, work out room-wise load and agree zones and controls.

2. Design & quotation

Outdoor and indoor selection, piping layout and a clear scope. Pricing is model- and site-specific; we do not publish a flat price list.

3. Install & test

Brazed copper under nitrogen, insulation, a long pressure hold and deep vacuum before the gas is released.

4. Commission & maintain

Test run, addressing, readings recorded in the handover report, then AMC visits to keep it efficient.

Go deeper

Related pages

VRF & VRV systems service

Our full VRF/VRV engineering scope, process and specifications.

Daikin VRV IV-S RXQ model

Model number, capacity, connected units and warranty.

VRV vs VRF: what is the difference?

A plain-language comparison, and when to choose which.

VRF maintenance guide

What facility managers should check and how often.

AMC plans

Bronze, Silver and Gold plans for VRV and VRF systems.

All Daikin products

Splits, cassettes, ductables and VRV from Daikin.

FAQs

Common questions

VRV (Variable Refrigerant Volume) is Daikin's name for the technology most other brands call VRF (Variable Refrigerant Flow). Both connect several indoor units to one inverter-driven outdoor unit and vary the refrigerant to each room. Daikin introduced VRV in 1982.

Planning a Daikin VRV system?

Share your drawings or book a site survey. We reply within 24 hours with questions, not a template quote.