One outdoor unit, many independently controlled rooms
A VRV system replaces a row of split-AC condensers with a single inverter outdoor unit connected to many indoor units by shared refrigerant piping. Each room keeps its own set-point, and the compressor slows down when only a few rooms need cooling, which is where the energy saving comes from.
We handle the full job: heat-load calculation, outdoor-unit and indoor-unit selection, copper piping layout, brazing under nitrogen, pressure and vacuum testing, charging by weight, and a commissioning report.
- Heat-load study room by room: orientation, glazing, occupancy and equipment
- Mixed indoor units on one system: wall, cassette and ductable
- Wired and wireless zone controllers, with BMS integration where the building needs it
- Written commissioning report and AMC options at handover
VRV IV-S for villas and small floors, modular VRV for larger buildings
The right size is set by the building's measured load, not by the number of rooms. We will say so if a ductable or cassette layout is cheaper for your space.
| VRV IV-S (compact) | Modular VRV (larger) | |
|---|---|---|
| Typical use | Villas, small offices, single retail floors | Multi-floor offices, hospitals, malls, hotels |
| Outdoor capacity | 5 HP to 14 HP (RXQ5T / RXQ8T / RXQ10T on our model page) | Modular combinations from 6 HP up to 64 HP |
| Indoor units | Up to 14 per system | Up to 64 per system, depending on combination |
| Refrigerant | R410A, factory charged | Per model: confirmed at quotation |
| Warranty on our model page | 1 year system + 5 years inverter scroll compressor | Confirmed per model at quotation |
From drawings to handover
1. Site survey & load study
We measure or take off drawings, work out room-wise load and agree zones and controls.
2. Design & quotation
Outdoor and indoor selection, piping layout and a clear scope. Pricing is model- and site-specific; we do not publish a flat price list.
3. Install & test
Brazed copper under nitrogen, insulation, a long pressure hold and deep vacuum before the gas is released.
4. Commission & maintain
Test run, addressing, readings recorded in the handover report, then AMC visits to keep it efficient.
Related pages
VRF & VRV systems service
Our full VRF/VRV engineering scope, process and specifications.
Daikin VRV IV-S RXQ model
Model number, capacity, connected units and warranty.
VRV vs VRF: what is the difference?
A plain-language comparison, and when to choose which.
VRF maintenance guide
What facility managers should check and how often.
AMC plans
Bronze, Silver and Gold plans for VRV and VRF systems.
All Daikin products
Splits, cassettes, ductables and VRV from Daikin.
Common questions
Planning a Daikin VRV system?
Share your drawings or book a site survey. We reply within 24 hours with questions, not a template quote.